![]() ![]() Extended integration times of 60–100 s have little effect on either precision or accuracy the marginal gains are in the intensity range where Daly outperforms Faradays. Faraday runs reach higher precisions at average intensities >2 mV (208Pb/207Pb data) Daly performs better at lowest intensities <400 µV (~20,000 cps 206Pb/204Pb data). Results of automated 1 h-long runs of NBS 982 with the Daly/photomultiplier system and ATONA amplifiers at three different integration times and a range of intensities. 18O/16O measured during our UO2 runs of zircon is consistent with the IUPAC recommended value of 0.002055. This effect has been identified for different storage conditions for the spike. ![]() Pb was analysed for 100–200 cycles (1.5–2.5h) following a single, long (3×300 s) baseline. Earthtime tracer solution as a function of the residual volume in the bottle. 207Pb/235U dates of the smallest GZ7 aliquots remain accurate despite large uncertainties for 207Pb beams of a few 10s µV. The accuracy of 206Pb/238U date appears to scale with average intensity of the limiting beam (205Pb or 206Pb depending on zircon size and spike weight), with a drop-off below ~1 mV. GZ7 aliquots were prepared in a range of sizes down to 1.7 pg Pb*. Synthetic solution data on loads >10 pg Pb* show good reproducibility and accuracy. 2018, GGR), the Earthtime 2 Ga and Early Time 4.5 Ga synthetic solutions. U–Pb FaraDaly dating results for shards of megacrystic zircon GZ7 (Nasdala et al. UO2: static Faraday routine allowing for simultaneous measurement of 18O/16O and UO2 interference corrections using mass 269īaseline: single at start, 300s at each half-mass Figure 4. Pb: 2-cycle FaraDaly routine with 204Pb (30s) alternated with 205Pb (10s) in the axial Daly photomultiplier (PM) to correct for Faraday–Daly gain. U–Pb methods and first results Measurement setup Cup configuration We observed a slight drift of gain values since installation on the order of 1 ppm across all channels. The gain values of all channels are highly reproducible over hours to days (default calibration time is 4 h). Gain calibration results since installation. Evolution of baseline parameters over time since installation (measured for 1h at 10 s integration period). a 1000 s integration period, one should be able to quantify a beam of 50–100 cps with a signal-to-noise ratio of ~5. The noise of the ATONA system improves with longer integration times, performing close to the theoretical (Johnson–Nyquist) noise of a 1012 Ω resistor at integration periods 100 s. Low amplifier noise is key to measuring small beams precisely. We present the results of our tests of the new ATONA system at Princeton University, the conditions in which it is advantageous to use it, and optimised Pb and U analysis methods.ĪTONA system at Princeton University Detector Parameters Figure 1.Better precision and accuracy for all but the smallest/youngest samples.Main advantages for TIMS U–Pb geochronology (compared to conventional ion counting with peak-hopping):.ATONA is a new Faraday cup signal amplifying technology for Isotopx Phoenix thermal ionisation mass spectrometers (TIMS).Department of Geosciences, Princeton University Key Points ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |